Information - Don't get caught unaware!

Safety Alerts

 

SAFETY ALERT NOTICE #1

 CM One Ton Series 622 Hand Chain Hoists

Also, various Grainger Hoists

Contact Info:           Larry P. Myhill, Service Manager

                                    Product Standards & Service

                                    Columbus-McKinnon Corporation

                                    800-634-4647 Extension #309

Recalled ID’s:          CM One Ton, Series 622

Grainger Stock #5W557 (CM #2204), #9FVC0 (CM# 2210), #2Z896 (CM#2217), #5W558 (CM# 2262), #9FKF0 (CM# 2264), and Special Grainger Stock# (CM #2204S).  Serial #: PT-B, or PU-B (located on hoist name plate)

Recall Statement:   CM advised that a number of 1 ton Series 622 Hand Chain Hoists, manufactured in June and July 2001, may contain a pawl spring that does not comply with manufacturing specifications and may provide a short service life.  Pawl spring fracture will result in the load being transferred to the hand chain and subsequent release of the hand chain will allow the load to drop, resulting in possible property damage and/or injury. 

Repair of these units under the recall procedure will require verification of Grainger stock number and serial number (PT-B or PU-B).

Action Required:    Remove unit from service, and send to a CM Master Parts Depot or Service Station.  Repair will involve replacement of pawl spring and load testing of the unit.  If you have one of these hoists call CM Contact above for further directions.

June / July 2001

 

SAFETY ALERT NOTICE #2

Square D Company – Class 9001 Multi-Speed

Pushbutton Pendant Inserts

Contact Info:           Neil W. Tollas, Director                                Bill Crum

                                    Logic Control Products                                Square D Company

                                    Square D Company                                     128 Bingham Rd

                                    8001 Highway 64E                                       Asheville, NC 28806

                                    Knightdale, NC 27545                                  828-255-1383                                  

919-266-3671

Recalled ID’s:          Square D – Class 9001 Type SKRU2, SKRU3, SHKU4 or SKRU5 Multi-Speed Push Button Operators Manufactured between January 1999 and August 1999.  The cartons and pushbutton operator will be marked with a date code of #9901 through #9940.

Recall Statement:   Square D has become aware that the Class 9001 Type SKRU2, 3, 4, or 5 multi-speed operators may randomly maintain their actuated state when pressure to the button is released.  A small percentage of the units may exhibit this condition.  Depending on the application, an operator remaining in its actuated state can result in unintended machine operation, leading to a potential for serious personal injury or property damage.  Note:  Class 9001 Type SKRU2, 3, 4, or 5 multi-speed operators are most often mounted in Class 9001 SKYP Pendant Stations, but may be used in other pendant or enclosure applications. 

Action Required:    Determine the date of manufacturing by checking the date code.  If you identify products with these date codes, make arrangements for immediate replacement of the operators by ordering a new device from your local Square D Distributor.  You will obtain full credit for the replacement operators by returning the old device to your local distributor. 

 

 

 

 

 

 

 

 

 

 

January to August 1999

 

SAFETY ALERT NOTICE #3

Allen-Bradley

Variable Depth Disconnect Switches

Contact Info:           Rockwell Automation                                                                       

Allen-Bradley Products                    

                                    Customer Service

440-646-5800

Recalled ID’s:          Allen-Bradley Bulletin 1494V Variable Depth Disconnect Switches 1494V-DS100 Series A, 1494V-NX10 Series A, 1494V-NX15 Series A, 1494V-DS200 Series B, 1494V-DH622 Series B, 1494V-DR622 Series B, 1494V-DHL622 Series B, 1494V-DRL622- Series B, 1494V-DN200 Series B, and 1494V-DNL200 Series B.  All affected units were manufactured before July 2000      

Recall Statement:   Rockwell Automations alert, states that in some of the units, bolts can become loose, dislodging the operating mechanism.  If this happens, the switch mechanism could be left on, even if the operating handle is turned to off, creating a shock hazard for maintenance personnel.

Action Required:    Rockwell Automation and Allen-Bradley recommend:

·        Continue using lockout/tagout procedures while working on equipment that is subject to disconnect switches such as the Bulletin 1494V.

·        Immediately inspect, per the preventive maintenance procedure, (can be found at www.msha.gov/ALERTS/Allen-Bradley.HTM) all Bulletin 1494V-DS200 Series B and DS100 Series A disconnect switches.  Check for missing or loose bolts as indicated.  If either of these conditions is found, or if there is a crack in the housing as indicated in the diagram, replace the switch.  A replacement switch will be provided at no charge by local distributors.  Material will be returned following the GTS SMS process.

·        Kit Catalog # 1494V-H13 should be installed to ensure that bolts remain secure.  This kit can be ordered from your local Allen-Bradley distributor at no charge.

 July 2000

 

SAFETY ALERT NOTICE #4

Crosby Swivel Hoist Rings

Contact Info:           Mr. Terry Johnson

The Crosby Group Inc.

                                    2801 Dawson Road

                                    Tulsa, OK 74110-5040

                                    1-800-772-1500

 Recalled ID’s:         Crosby Swivel Hoist Rings

                                    HR-125 Series – 1.50” (24,000# WLL), PN 1016986

                                    HR-125 Series – 2.00” (30,000# WLL), PN 1016997

                                    HR-125M Series – M 36 (11,000kg WLL), PN 1016690

                                    HR-125M Series – M 42 (12,500kg WLL), PN 1016701

                                    HR-125M Series – M 48 (30,000kg WLL), PN 1016712           

The only items recalled are the above items with the Product Identification Code “Y5C” marked on the bail, or “Z7C” marked on the bolt.                  

Bail Product ID Code Possible Locations

Bolt Product ID Code Location

    WLL Location

HR-125 Product Identification Code Locations

Recall Statement:   READ THIS WARNING CAREFULLY !  Failure to heed this warning may result in property damage, severe injury, or death.   The Crosby Group has been made aware of a potential hazard in the use of the above listed size Crosby HR-125, and HR-125M Swivel Hoist Rings, if they were produced in the stated production run.

Action Required:   These specific size Swivel Hoist Rings, which are marked with the referenced Product Identification Codes, shall be taken out of service immediately, and returned to The Crosby Group for Inspection. 

·        The end user shall immediately inspect all stock, whether in use or in inventory, and return to the Distributor to arrange for replacement. 

·        Distributors are to obtain a Return Goods Authorization, identify and return all designated Swivel Hoist Rings.      

April 8, 2003

 

SAFETY ALERT NOTICE #5

Weigh-Tronix / Dillon

Model AP Dynamometers and Crane Scales

Contact Info:           Recall Hotline

Weigh-Tronix, Inc.

Dillon Division

                                    1-800-368-2031

 Recalled ID’s:          Dillon Model AP Dynamometers and Crane Scales with

Serial Numbers 6620 through 7971 shipped between

June 13, 1996 and December 4, 1996, with a

capacity of between 4,000 and 20,000 pounds.  

Recall Statement:   Dillon has advised that some Model AP Dynamometers and Crane Scales have been manufactured from substandard materials.  A dynamometer failure during lifting could result in an injury, fatality, or equipment damage.

Action Required:   Remove these units from service immediately!  Contact Weigh-Tronix Inc. for further assistance. 

                     ED-2000 large Photo

 December 18, 1996

 

SAFETY ALERT NOTICE #6

Weigh-Tronix / Dillon

Model AN and ANC Dynamometers

Contact Info:           Recall Hotline

Weigh-Tronix, Inc.

Dillon Division

                                    1-800-368-2031

Recalled ID’s:          ALL Dillon Model AN and ANC Dynamometers

Recall Statement:   Dillon has issued a Notice of Product Service Termination on all models AN and ANC Dynamometers.  A dynamometer failure during lifting could result in an injury, fatality, or equipment damage.

Action Required:   Remove these units from service immediately!  These units should be permanently taken out of service.  These units could be at the end of their useful safe working life.  These models were last manufactured in 1976 some are more than 50 years old.   On March 28, 1996, at the Navy Reactor Facility at INEL, a 20,000 pound capacity Dillon Model AN failed while lifting 8,500 pounds.  Investigators determined failure occurred because of brittle fracture. 

May 1, 1996